Mfg Part Number: PP3611TRN17 | Manufacturer: Joint Electronics Type Designation | NSN : 6120-00-078-7610 |
Item Name : power supply | CAGE Code : 80058 | FSC : 6120 Transformers Distribution and Power Station |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 26.000 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 7.500 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 22.500 INCHES NOMINAL |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 115.0 AC VOLTS NOMINAL SINGLE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 1.2 DC KILOVOLTS NOMINAL 2ND POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 3.0 DC KILOVOLTS NOMINAL 1ST POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 60.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
CBBL | FEATURES PROVIDED | FILTER |
CWGH | OUTPUT CURRENT RATING | 200.0 DC MILLIAMPERES NOMINAL 2ND POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 250.0 DC MILLIAMPERES NOMINAL 1ST POWER OUTPUT |
FEAT | SPECIAL FEATURES | FULL RECTIFICATION |
ZZZV | III FSC APPLICATION DATA | BEACON SET,RADIO NAVIGATION,NON-AIRBORNE |
![]() |