Mfg Part Number: 97F8515FC | Manufacturer: General Electric Inc | NSN : 5910-01-136-3933 |
Item Name : capacitor fixed pla | CAGE Code : 01002 | FSC : 5910 Capacitors |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | W/O MTG FACILITIES, TERMINAL(S) ON ONE SURFACE |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 1.180 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 2.910 INCHES NOMINAL |
ADAT | BODY WIDTH | 1.910 INCHES NOMINAL |
ADAU | BODY HEIGHT | 5.750 INCHES NOMINAL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.380 INCHES NOMINAL |
AEBT | TERMINAL DIAMETER | 0.250 INCHES NOMINAL |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
CBBL | FEATURES PROVIDED | HERMETICALLY SEALED CASE |
CQBQ | CAPACITANCE VALUE PER SECTION | 15.000 MICROFARADS SINGLE SECTION |
CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 75.0 DEG CELSIUS MAXIMUM |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 350.0 AC-PEAK SINGLE SECTION |
CRTP | TOLERANCE RANGE PER SECTION | -10.00/+10.00 PERCENT SINGLE SECTION |
CWJK | CASE MATERIAL | METAL |
CWPK | INSULATION RESISTANCE AT REFERENCE TEMP | 50000.0 MEGOHMS |
TTQY | TERMINAL TYPE AND QUANTITY | 2 THREADED STUD |
![]() |